0m) € 68,80. It shares the same features as the D2-260 CPU. 110VAC 16PT Input Direct Logic. This version of Internet Explorer is either no longer supported by Microsoft , or is obsolete and some features of our store may no longer be supported. . † D2-04TD1 ² 10 Feedthrough ZL-RTB20 (-1) ZL-D2-CBL10 ZL-D2-CBL10-1 ZL-D2-CBL10-2 D2-08TD1 D2-08TD2 D2-16TD1-2 19 Feedthrough. You will need to know the Legacy Ziplink module you are using now and the PLC I/O module that you are. Table of Contents. ZL-D2-CBL10 ZL-D2-CBL10-1 D2-08NA-2 10 ZL-D2-CBL10-2 D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. 00 Poi nt s 16 12 8 4 0 0 Derat i ng Chart 80-132 VAC IN 0 See Wiring Solutions for part numbers of ZIPLink cables and connection modules compatible. 00 2600 None D2-06B-1 $268. Requires P2-RTB or P2-RTB-1 removable terminal. $110. How the non-volatile V-memory works in the D2-230, D2-240 and DL05 CPUs AN-MISC-007 Recommended method of connecting to 32pt and 64pt 205/405 I/O modules with High-Density Connector D2-04TRS D2-08TR D2-12TR ZL followed by -TSD8 followed by -24 or -120. 5m, -1 = 1. each. Cable PartD2-08NA-1 D2-16NA 1 In 2 In 14H 08H DC Output 4 pt 12-24 VDC 8 pt 12-24 VDC 16 pt 12-24 VDC 16 pt 12-24 VDC 32 pt 12-24 VDC D2-04TD1 D2-08TD1 D2-16TD1-1 D2-16TD1-2 D2-32TD1 1 Out 1 Out 2 Out 2 Out 4 Out 0AH 13H 06H 06H 0FH Specialty Modules 8 pt Input Simulator F2-08SIM 1 In 14H AC Output 8 pt 18-220 VAC 12 pt 18-220 VAC D2. D2-08NA-2 2. D2-16ND3-2 Sink/Source Discrete Input Module Model: Qty: 2. 00. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. Any help would be greatly appreciated. Do-more H2 Series PLC User Manual, 1st Edition, Rev. D2-16ND3-2 D2-32ND3 AC 80–132 VAC D2-08NA-1 D2-16NA 170–265 VAC D2-08NA-2 Note 1: D2-08CDR is a combo I/O module that has four discrete input and four discrete output points. Automationdirect's D2-08TR is a dc i/o plc plc module. Loading. Please call or email us with your request. Choose from 25 different discrete. ×Sorry to interrupt. Wiring Diagram for AC Inductive and Photo type sensors with the D2-16NA. Use this cross-reference table if you're looking for the equivalent PLC Direct parts for your "old" GE or TI/Siemens PLC system. D2 D3 CIV A4 A5 A6 A7 CI B4 B5 B6 B7 CII C4 C5 C6 C7 CIII D4 D5 D6 D7 D2-32ND3-2 ACT IN 5-15 VDC 5-15VDC 4-14mA CLASS2 CO+ DC Input Modules D2-32ND3 DC Input $190. Should do the multiplexing or pointers or neither. Order international: +1 609. D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 0DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. , Relay Output 2–50 Glossary of Specification Terms 2–51 Chapter 3:. $110. Koyo DirectLOGIC 205 PLC D2-16ND3-2 Digital I/O Module, 16 digital input (24V DC) - DirectLOGIC 205 PLC DIO ModulesThe D2-INST-M installation and I/O Manual covers information about DL205 I/O modules, power budgeting, and installation and wiring. Productivity2000 discrete input module, 16-point, 120-240 VAC, 2 isolated common (s), 8 point (s) per common. Cable Part No. $155. dl205 zl-2cbl2l d2-16na zl-cm16l120 warning : wire only according to wiring diagrams shown below to avoid causing damage to the plc or connector module. D2-16ND3-2 Sink/Source Discrete Input Module Model: Qty: 2. Call 800-575-5562 to schedule On-Site Service today. Manufacturer: Automationdirect. 5500. 00 more info;Our free 2-year warranty makes every Radwell purchase a dependable, reliable investment in your company's future. Please call or email us with your request. We. . 00 Inputs per Module 32 (sink/source) Commons per Module 4 isolated (8 I/O terminal points / com) Input Voltage Range 20-28 VDC Peak Voltage 30VDC ON Voltage Level. Module=”D2-16NA 16PT DISCRETE INPUT” 0x11 EndModule This Errata Sheet contains corrections or changes made after the publication of this manual. INPUT: D2-16NA. DL205 PLC. We use the mid-market rate for our Converter. in the panel controls and displays, plc modules category. Koyo DirectLOGIC 205 PLC D2-16NA Digital I/O Module, 16 digital input (100V AC) - DirectLOGIC 205 PLC DIO Modules - LayoutD2-08NA-2 10 ZL-D2-CBL10-2 D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. D2-08CDR 10 Feedthrough ZL-RTB20 (-1) ZL-D2-CBL10 * Do-more/DL205 PLC Analog Module ZIPLink Selector PLC ZIPLink Analog Module # of TermsDL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. 5 oz. 5–6 Do-more H2 Series PLC Hardware User Manual, 1st Edition, Rev. D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0D2-04b Automation Direct Logic 205 PLC Chassis D204B N110. 26–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay ModulesD2-CTRINT F2-CP128 D2-EM D2-DCM Programming Software The Do-more H2 Series PLC can only be programmed by Do-more Designer. Ask us about D2-16NA Repairs. 110V AC 16 Input Module D2-16NA. Order international: +1 609. You won’t receive this rate. Webster, NY, United States. Part Number Cross-Reference. 2101: RFQ: D3-USER-M: directlogic : directlogic dl305 user manual, free download only. It’s as simple as. OUTPUT: D2-12TA. 288. D2-08NA-2 10 Feedthrough ZL-RTB20 ZL- D2-C BL10* D2-16NA 19 Feedthrough ZL-RTB20 ZL-D 2-C BL19* DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component26–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay ModulesD2-16NA AC Input <---> Inputs per Module 16 Commons per Module 2 (isolated) Input Voltage Range 80-132 VAC Peak Voltage 132 VAC ON Voltage Level 70 VAC minimum OFF Voltage Level 20 VAC maximum AC Frequency 47-63 Hz Input Impedance 12 k @ 60 Hz Input Current 11 mA @ 100 VAC, 50 HzAutomationDirect F2-08AD-2 Installation And I/O Manual (122 pages) DirectLOGIC DL205 series. (visit site 1999 Chevy Silverado Fuse). Order international: +1 609. D2-16NA AC Input $204. $159. com. Warranty Terms and Conditions. 3 oz. Order international: +1 609. $200. Minimum Repair Price is $200. $8. directlogic dl205 discrete input module, 16-point, 120 vac, 2 isolated common(s), 8 point(s) per com. D2-260 (CPU) D2-16ND3-2 D2-16ND3-2 D2-16NA D2-08NA-1 D2-16TD1-2 D2-08TA D2-08TA 330 100 100 100 50 200 250 250 0 0 0 0 0 80 0 0 D OTHER Operator interface Handheld programmer DV-1000 D2-HPP 150 200 0 0 E Maximum Current Required 1730 80 F Remaining Current Available 2600-1520=1080 300-80=220 Power Supply SpecificationsD2-04TRS D2-12TR ZL followed by -LTB16 or -LTB32 followed by -24. Brand: AutomationDirect | Category: I/O Systems | Size: 3. Switch location drill a hole to allow the wire. 884. It’s as simple as. Repairable. match the correct combination of cable, plc i/o module, and connector module as shown. † D2-04TD1 ² 10 Feedthrough ZL-RTB20 (-1) ZL-D2-CBL10 ZL-D2-CBL10-1 ZL-D2-CBL10-2 D2-08TD1 D2-08TD2 D2-16TD1-2 19 Feedthrough. Product Dimensions : 4 x 3. or Best Offer. 37Our free 2-year warranty makes every Radwell purchase a dependable, reliable investment in your company's future. Each specific module's documentation shows it's I/O numbering for the DL but. 00 more info; out of stock. Back Shopping Cart (0) Support; Home;Buy the PLC Direct 198136GR from NIControls. See all 78. 5. example connect a b a1-c 01 2 3456 type connection for sensor dc configuration npn a1a1a1a1a1 a1a1 a2a2a2. Module=”D2-08ND3 8PT DISCRETE INPUT” 0x10 EndModule Module=”D2-16ND3-2 16PT DISCRETE INPUT” 0x11 EndModule Module=”D2-32ND3 32PT DISCRETE INPUT” 0x13. followed by -TR, may be followed by S or S-1. 15 Programmable Logic Controller (PLC) Relay Output Module Automation Direct F2 -08TRS In order to match other products in use on County facilities either completed or in. The D2-DCM Data Communications Module is used primarily for three reasons: • Extra communications port to connect a PC, operator interface, etc. Toggle menu. 00. D2-16TD2-2 Discrete Output Module Model: Qty: 2. D2-250-1 Communications Port: The D2-250-1 CPU has a 15–Pin connector on Port 2 that provides a built–in Modbus RTU or DirectNET master/slave connection. D2–DSCBL–1 on port 2 Mounting depths with: 2-6 DL205 User Manual, 5th Edition, Rev. Please call or email us with your request. 5 oz. $20. 5500. D2-16TD2-2 Discrete Output Module. F - H2-DM-M. 288. 1A A0 A1 A2 A3 CI B0 B1 B2 B3 CII C0 C1 C2 C3 CIII D0 D1 D2 D3 CIV A4 A5 A6 A7 VI B4 B5 B6 B7 VII C4 C5 C6 C7 VIII D4 D5 D6 D7 VIV D2-32TD1 ACT OUT 12-24 VDC. D2-04TD1 ² 10 Feedthrough ZL-RTB20 ZL-D 2-C BL10* D2-08TD1 10 Feedthrough ZL-RTB20 ZL-D 2-C BL10*D2-260 (CPU) D2-16ND3-2 D2-16ND3-2 D2-16NA D2-08NA-1 D2-16TD1-2 D2-08TA D2-08TA 330 100 100 100 50 200 250 250 0 0 0 0 0 80 0 0 D OTHER Operator interface Handheld programmer DV-1000 D2-HPP 150 200 0 0 E Maximum Current Required 1730 80 F Remaining Current Available 2600-1520=1080 300-80=220 Power Supply SpecificationsD2-08NA-2 10 Feedthrough ZL-RTB20 ZL- D2-C BL10* D2-16NA 19 Feedthrough ZL-RTB20 ZL-D 2-C BL19* DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. directlogic dl205 discrete input module, 16-point, 120 vac, 2 isolated common(s), 8 point(s) per com. ZL-TSD120 ZL-TSD824 ZL followed by -RFU followed by 20 or 40. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. New Surplus: Call Now: In Stock Buy Now: Reconditioned: Call Now: In Stock Buy NowDirect Automation. Buy Surplus As Low As. 15 MB. D2-04TRS D2-08TR D2-12TR ZL followed by -TSD8 followed by -24 or -120. Specifications. D2-16NA: directlogic : directlogic dl205 discrete input module, 16-point, 120 vac, 2 isolated common(s), 8 point(s) per common. in the panel controls and displays, plc modules category. If you have problems viewing a PDF document or wish to save a PDF, right-click on the link to the document, select "Save Target As" or "Save As", and select the location where the file will be saved. D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0D2-16NA 16-pt 110VAC $142. ZL-TSD120 F2-UNICON ZL followed by -RFU followed by 20 or 40. Table of Contents. 1A A0 A1 A2 A3 CI B0 B1 B2 B3 CII C0 C1 C2 C3 CIII D0 D1 D2 D3 CIV A4 A5 A6 A7 VI B4 B5 B6 B7 VII C4 C5 C6 C7 VIII D4 D5 D6 D7 VIV D2-32TD1 ACT OUT 12-24 VDC. 5 oz. D2-16ND3-2 PLCs/Machine Control from AUTOMATION DIRECT In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - INPUT MODULE, DIRECTLOGIC, DL205, DISCRETE, 16-POINT, 24 VDC, SINKING/SOURCING, 2 ISOLATED COMMON (S), 8 POINT (S) PER COMMON. Step 2 Locate compatible connector module type. 709-COB103 Contactors & Starters from ALLEN BRADLEY 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, STARTER, SIZE 2, 3 PHASE, 3 POLE, COIL: 120/110 VAC, 50/60 HZ. Home; Products; Support; Downloads; Contact; Products. D2-16NA € 242,80 Quantity per package: 1 – 16-pt. D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 0(D2-250-1 and D2-262 CPUs) 2 output channels per scan maximum: (D2-262 CPU) Base Power Required 5VDC 90mA External Power Supply Requirement 18-26. D2-16NA - 16 pt. D2-16NA - DL205 discrete input module, 16-point, 120 VAC, 2 isolated common(s), 8 point(s) per common. plc direct. Add to quote requestDL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. 4–6 Do-more H2 Series PLC Hardware User Manual, 1st Edition, Rev. 91 1 $165. D2-16ND3-2 D2-16ND3-2 D2-16NA D2-08NA-1 D2-16TD1-2 D2-08TA D2-08TA 275 100 100 100 50 200 250 250 0 0 0 0 0 80 0 0 D OTHER Operator interface EA1-S3ML 90 0 E Maximum Current Required 1415 80 F Remaining Current Available 2600-1415=1185 300-80=220. D2-250 to Serial printer/data terminal using RS-232. PLC Direct DirectLogic 205 - DL205 discrete input module, 16- point, 120 VAC, 2 isolated common (s), 8 point (s) per common. Product group: 205 series Information Type: 16 point AC input module Last revised : 15. Page 83: D2-16Na, Ac Input Chapter 5: Specifications - Discrete I/O Modules D2-16NA, AC Input D2-16NA AC Input Inputs per Module Commons per Module 2 (isolated) Input Voltage Range 80–132 VAC Peak Voltage 132VAC ON Voltage Level 70VAC minimum OFF Voltage Level 20VAC maximum AC Frequency 47–63 Hz Input Impedance 12kq @ 60Hz. Starting at. It’s as simple as. 26–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay ModulesD2-08ND3 10 Feedthrough ZL-RTB20 ZL-D2-CBL10 * D2-16ND3-2 19. Programmable Controllers Certified for CanadaSlot1 D2–16NA +100 +0 Slot2 D2–16NA +100 +0 Slot3 F2–04AD–1 +50 +80 Slot4 F2–02DA–1 +40 +60 Slot5 D2–08TA +250 +0 Slot6 D2–08TD1 +100 +0 Slot7 D2–08TR +250 +0 Other HandheldProgrammer D2–HPP +200 +0 TotalPowerRequired 1670 140 RemainingPowerAvailable 2600–1670=930 300–140=160. D2-16NA is a discrete AC input module manufactured by Automation Direct, Facts Engineering, and Koyo. 110V AC 16 Input Module D2-16NA. 00 8 pt. Ask us about D2-16NA Repairs. If you need a specific firmware or series relating to D2-12TR, we probably have it. AutomationDirect D2-16NA Installation And I/O Manual (122 pages) DirectLOGIC DL205 series. ZL-RFU20 D2-DCM D2-RMSM D2-RSSS SGW-MB1524-T ZL followed by -TSD8 followed by -24 or -120. Anyone can obtain information about the validity of a given certification by contacting the UL Customer Experience Center. 2 Caution: The D2-04TD1, D2-04TRS, and F2-08TRS outputs are derated not D2-260 (CPU) D2-16ND3-2 D2-16ND3-2 D2-16NA D2-08NA-1 D2-16TD1-2 D2-08TA D2-08TA 330 100 100 100 50 200 250 250 0 0 0 0 0 80 0 0 D OTHER Operator interface Handheld programmer DV-1000 D2-HPP 150 200 0 0 E Maximum Current Required 1730 80 F Remaining Current Available 2600-1520=1080 300-80=220 Power Supply Specifications D2-16NA - DirectLOGIC DL205 discrete input module, 16-point, 120 VAC, 2 isolated common (s), 8 point (s) per common. The default configuration for all of the Do-more CPUs is to automatically map the I/O points for the on-board Discrete inputs and outputs and all of the discrete I/O modules, beginning in the slot adjacent to the CPU, and proceeding from left to right across the base, allocating discrete input and output memory as each module requires. Jamie Marshall. D2-08NA-2 8 Pt 170-265 VAC Input, 2 Commons D2-16NA 16 Pt 110 VAC Input F2-08SIM 8 Pt Switch Slide Simulator D2-04TD1 4 Pt 12-24 VDC Sink Output D2-08TD1 8 Pt 12-24 VDC Sink Output D2-16TD1-2 16 Pt 12-24 VDC Sink (2 Terminals) D2-08TD2 8 Pt 12-24 VDC Source OutputSE-SW5U-WT D2-08TR SE-SW9U-ST-WT T1F-08DA-1 D3-016TD1-2 D2-09BDC-2-1 D2-260 P3 followed by -16 followed by AD or DA, followed by -1 or -2. Get the best deals for automationdirect d4-16na at eBay. aa eeD2-08NA-2, AC Input 2–34 D2-16NA, AC Input 2–35 F2-08SIM, Input Simulator 2–35 D2-04TD1, DC Output 2–36 D2–08TD1, DC Output 2–37. LoginKoyo DirectLOGIC 205 PLC D2-16NA DIO, 16I. Order international: +1 609. com, a global distributor of. ×Sorry to interrupt. D2-04b Automation Direct Logic 205 PLC Chassis D204B N110. D2-250 CPU Processor Module. 00 8 pt. D2-08NA-2 10 ZL-D2-CBL10-2 D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. 9393. $110. Brand: AutomationDirect | Category: I/O Systems | Size: 3. 9393. Overview KOYO D2-16NA MODULE Also known as: D216NA, KOYD216NA Specifications Customer Reviews No reviews for this product (0) Write a. Koyo D2-09B Direct Logic 205 PLC D2-16NA. B endi D222 eiations CPU Overview The D2-262 CPU is an addition to the DL205 system. D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. 220VAC D2-16NA $135. DL205 InstaLLatIon anD I/o MANUAL Please include the Manual Number and the Manual Issue, both shown below, when communicating with Technical Support regarding this. Drum Terminology Drum instructions are best suited for repetitive processes that consist of a finite number of steps. $200. Free shipping. Tags:D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 0D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. D2-16NA specifics: 16 AC inputs (80~132 VAC) Specifications Quantity per product 1 Short Description. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. D2-16ND3-2 D2-32ND3 AC 80–132 VAC D2-08NA-1 D2-16NA 170–265 VAC D2-08NA-2 Note 1: D2-08CDR is a combo I/O module that has four discrete input and four discrete output points. Shopping Cart (0) Login. We don't know when or if this item will be back in stock. 00 DL205 Discrete Output Modules D2-04TD1 4-pt 12-24VDC sink $71. REMOVABLE TERMINAL BLOCK INCLUDED. *Caution: The D2-04TD1, D2-04TRS, and F2-08TRS outputs are derated not to exceed 2 Amps per point and 2 Amps per common when used with the ZIPLink wiring system. Discrete 110 VAC and 12-24 VDC input modules are available in 8- and 16-point versions. . Product Category The Product Category, also known as the UL Category Description, describes the product classification under which an item or product is listed. Please call or email us with your request. ) Compatibility Matrix Chart For 05/06 PLCs I/O Modules Feed-through ModulesRelay Modules Fuse Modules LED ModulesD2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 0d3-16na,d3-16ne3,d3-16td1-1 d3-16td2,d3-16ta2 d3-16nd2-2,d3-16td1-2 d4-08nd3s 0n0 1n0 2n0 3n0 4n0 5n0 6n0 7n0 in7 in3 in0 in0 in2 in2 in4 in4 in6 in6 a4 a5 a6 a7 ci b4 b5 b6 b7 cii c4 c5 c6 c7 ciii d4 d5 d6 d7 civ d4-32nd3-1,d4-32nd3-2 a0 a1 a2 a3 ci b0 b1 b2 b3 cii c0 c1 c2 c3 ciii d0 d1 d2 d3 civ d4-32td1,d4-32td1-1 d2-32nd3,d2-32nd3-2d2-08nd3 d2-16nd3-2 d2-08na-1 d2-08na-2 d2-32nd3 d2-16na. com. Discrete Output Modules Output Type Specification Number of Output Points per Module 4 8 12 16 32 DC (Sinking) 4A @ 10. plc direct. DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. 00 D2-08TD1 8-pt 12-24VDC sink $60. Warranty Terms and Conditions. D2-08NA-2 No D2-16NA D2-16NA No D2-04TD1 Specialty Modules D2-04TD1 D2-08TD1 D2-08TD2 D2-08TD2 No D2-16TD1-2 D2-16TD1-2 D2-16TD2-2 D2-16TD2-2 F2-16TD1P D2-12TR - DirectLOGIC DL205 relay output module, 12-point, 6-24 VDC/6-240 VAC, (12) Form A, 2 common(s), 6 point(s) per common, 1. D2-16NA 19 Feedthrough ZL-RTB20 ZL-D2-CBL19 * Do-more/DL205 PLC Analog Module ZIPLink Selector PLC ZIPLink Analog Module # of Terms Component Module Cable F2-04AD-1 10 Feedthrough ZL-RTB20 ZL-D2-CBL10* F2-08AD-1 F2-04AD-2D2-04TRS D2-08TR D2-12TR ZL followed by -TSD8 followed by -24 or -120. , Relay Output 2–50 Glossary of Specification Terms 2–51 Chapter 3:. D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. ac; dc; cables; plc; Share. DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. Two year warranty included on all parts. Module=”D2-16NA 16PT DISCRETE INPUT” 0x11 EndModule This Errata Sheet contains corrections or changes made after the publication of this manual. Call us at 905-461-0001 for your Industrial Needs. com®. D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0D2-16NA In Stock! Automation Direct Koyo PLC Direct 16 Point 110 VAC Input Module. 5500. D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. 00. com. D2-16NA AC Input <---> Inputs per Module 16 Commons per Module 2 (isolated) Input Voltage Range 80-132 VAC Peak Voltage 132 VAC ON Voltage Level 70 VAC minimum OFF Voltage Level 20 VAC maximum AC Frequency 47-63 Hz Input Impedance 12 k @ 60 Hz Input Current 11 mA @ 100 VAC, 50 HzIf you need a specific firmware or series relating to M050-11612, we probably have it. Tags: layout, Koyo, Programmable Logic Controllers (PLC) Edit SVG PNG JPG DXF DWG. It’s as simple as. Automationdirect's D2-32TD1 is a dc i/o plc plc module. Order international: +1 609. 15 MB. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. Brand: AutomationDirect | Category: I/O Systems | Size: 3. $8. Overview KOYO D2-16NA MODULE Also known as: D216NA, KOYD216NA. PLC Hardware. D2-08NA-1 AC Input $116. **The F2-08TR outputs are derated not to exceed 2 Amps per point and 4 Amps per common when used with the ZIPLink wiring system. 1. Specifications. D2–08CDR 4 pt. (65g) D2-08TD2 2. 00 shipping. Datasheet. DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. SE-SW9U-ST-WT H0-ECOM100 SE-SW5M H2-WPLC3 may befollowed by additional letter(s) a nd/or. Order international: +1. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. com. Automationdirect's D2-16NA is a dc input plc modules. Requires P2-RTB or P2-RTB-1 removable terminal block or ZIPLink pre-wired cables. D2-08NA-2 10 ZL-D2-CBL10-2 D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output. 00 Inputs per Module 16 Commons per Module 2 (isolated) Input Voltage Range 80-132 VAC Peak Voltage 132VAC ON Voltage Level 70VAC minimum OFF Voltage Level 20VAC maximum AC Frequency 47-63 Hz Input Impedance 12 kΩ @ 60 Hz Input Current 11mA @ 100VAC, 50Hz 13mA @ 100VAC, 60HzKoyo DirectLOGIC 205 PLC D2-16NA Digital I/O Module, 16 digital input (100V AC) Stencil: DirectLOGIC 205 PLC DIO Modules - Layout. 00 2600 300 Power Consumed Device 5V(mA) 24V Auxiliary CPUs D2-262 336 0 DC Input Modules D2-08ND3 50 0 D2-16ND3-2 100 0 D2-32ND3 25 0 D2-32ND3-2 25 0 AC Input Modules D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0. Warranty Terms and Conditions. Description: Input DC Modules. Cable Part No D2–32ND3(–2) 32 Input H2–ERM(100,–F) None AC Input Modules H2–EBC(–F) None D2–08NA–1 8 Input D2–RMSM None D2–08NA–2 8 Input D2–RSSS None D2–16NA 16 Input F2–CP128 None DC Output Modules H2–CTRIO(2) None D2–04TD1 8 Output (Only the first four points are used) D2–CTRINT 8 Input 8 Output D2-08ND3 50 0 D2-16ND3-2 100 0 D2-32ND3 25 0 D2-32ND3-2 25 0 AC Input Modules D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 1000 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 Power Supplied Device 5V(mA) 24V Auxiliary Device 5V(mA) 24V. Order international: +1. Warranty Terms and Conditions. Order toll free: 800. 00 repair yours. removable terminal block included. SE-SW9U-ST-WT H0-ECOM100 SE-SW5M H2-WPLC3 may befollowed by additional letter(s) a nd/or. † D2-04TD1² 10 Feedthrough ZL-RTB20 ZL-D2-CBL10* D2-08TD1 10 Feedthrough ZL-RTB20 ZL-D2-CBL10* D2-08TD2. The D2-240 has a total of 320 X input, 320 Y outputs, and 256 control relays available to share between local and remote I/O. AC input module for Koyo DL205 and Do-more PLC +31 (0)318 528020. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. followed by -TR, may be followed by S or S-1. 00. match the correct combination of cable, plc i/o module, and connector module as shown. DL205 ZIPLink cable for discrete I/O modules up to 16 pt and 12 channel analog I/O modules, 0. D2-16NA: directlogic : directlogic dl205 discrete input module, 16-point, 120 vac, 2 isolated common(s), 8 point(s) per common. Therefore, a D2-16NA (for example) uses X0-X15 where in a DL PLC it would be X0-X7/X10-X17. ZL-RFU20 P308TRS followed by -TR, may be followed by S or S-1. Expand Post Power supplies provide the DC power needed for proper controller operation. AutomationDirect D2-08ND3 (D208ND3) Input Module. $22. 00 2600 None D2-06B-1 $268. In several different qualities If you are wanting. (100g) Title: Do-more! H2 Series PLC Hardware User Manual Author: AutomationDirect Subject:D2-16NA 110V AC 16 Input Module Model: 16NA Qty: 1. Discrete I/O Modules Overview. Automation Direct D2-16NA DirectLOGIC DL205, 16-point, 120 VAC, (ONE PIECE) $79. Manual Number: D2–USER–M Edition/Rev Date Description of Changes Original 1/94 original issue Rev A 9/95 minor corrections 2nd Edition 6/97 added DL250, downsized manual Rev A 5/98 minor corrections Rev B 7/99 added torque specs for base and I/O Rev C 11/99 minor corrections Rev D 03/00 added new PID features, minor correctionsD2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 0D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 0Product Category The Product Category, also known as the UL Category Description, describes the product classification under which an item or product is listed. 3. J - H2-DM-M Cater Seiations - Disrete Modules D2-16ND3-2, DC Input D2-16ND3-2 DC Input Inputs per Module 16 (sink/source) Commons per Module 2 isolated (8 I/O terminal points/com) Input Voltage Range 20–28 VDC Peak Voltage 30VDC (10mA) ON Voltage Level 19VDC minimum. asked Sep 11, 2022 at 18:09. (80g) F2-16TD1P 2. NOTE: For the latest information on agency approvals, check our Web site. Cable Part No. D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 026–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay ModulesOn-Site Service is available for your Direct Logic* D2-16NA. D2-08ND3 10 Feedthrough ZL-RTB20 ZL-D2-CBL10* D2-16ND3-2 19 FeedthroughZL-RTB20 ZL-D2-CBL19* Sensor ZL-LTB16-24 ZL-D2-CBL19* D2-32ND3¹ 40. 202 Heavy Duty 1/8 to 2" Model 202 Wide Roll Pipe Cutter. Programmable Controllers for Use in Hazardous Locations Certified for CanadaD2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 0D2-03B-1 DL240 CPU D2-16NA D2-12TA. com. 00 2600 None D2-09BDC1-1 $360. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. automation direct. . 00 2600 None D2-06B-1 $268. com. Check prices, availability and buy online instantly. End of Search Dialog. J - H2-DM-M Cater Seiations - Disrete Modules D2-16ND3-2, DC Input D2-16ND3-2 DC Input Inputs per Module 16 (sink/source) Commons per Module 2 isolated (8 I/O terminal points/com) Input Voltage Range 20–28 VDC Peak Voltage 30VDC (10mA) ON Voltage Level 19VDC minimum. (56g). D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM 50 0 DC Output Modules D2-04TD1 60 20 D2-08TD1 100 0 D2-08TD2 100 0 D2-16TD1-2 200 80 D2-16TD2-2 200 0 F2-16TD1P 70 50 F2-16TD2P 70 50 D2-32TD1 350 0 D2-32TD2 350 0 AC Output Modules D2-08TA 250 0 F2-08TA 250 0 D2-12TA 350 0TABLE OF CONTENTS Chapter 1 - Getting Started Introduction. 884. † D2-04TD1 ² 10 Feedthrough ZL-RTB20 (-1) ZL-D2-CBL10 ZL-D2-CBL10-1 ZL-D2-CBL10-2 D2-08TD1 D2-08TD2 D2-16TD1-2 19 Feedthrough. D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output1747-L553 New Sealed AB / C SLC500 5/05 CPU Processor Unit 1747L553 HT 1PCS. D2-16NA 【Input】Points:16 Function:100 V AC: F2-08SIM 【Input】Points:8 Function:Simulator: Extension IO module Output Module. D2-16NA D2-08NA-1 D2-16TD1-2 D2-08TA D2-08TA 275 100 100 100 50 200 250 250 0 0 0 0 0 80 0 0 D OTHER Operator interface EA1-S3ML 220 0 E Maximum Current Required 1545 80 F Remaining Current Available 2600-1545=1055 300-80=220 Power Supply Specifications Specification AC Powered Bases 24VDC Powered Bases 125VDC. Discrete Inputs are mapped into X memory,. com. WE ARE HAPPY TO HELP! ORDERS PUT IN BEFORE 8 AM WILL GO OUT. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. D2-250-1, D2-260 or D2-262 CPUs only) and DL405 CPU systems in high– speed, peer–to–peer networks. Automationdirect F2-08TR Pdf User Manuals. Our free 2-year warranty makes every Radwell purchase a dependable, reliable investment in your company's future. Analog I/O Modules The following table may be helpful for you to select the right modules for your application. D2-16TD1-2 16-Point DC Output Module Model: Qty: 5. Rush Available. com. No remote I/O for D2-230 D2-240, D2-250(-1), D2-260 support a maximum of 2048 points per channel. $179. Worldwide Shipping available. Page 83: D2-16Na, Ac Input Chapter 5: Specifications - Discrete I/O Modules D2-16NA, AC Input D2-16NA AC Input Inputs per Module Commons per Module 2 (isolated) Input Voltage Range 80–132 VAC Peak Voltage 132VAC ON Voltage Level 70VAC minimum OFF Voltage Level 20VAC maximum AC Frequency 47–63 Hz Input Impedance 12kq @ 60Hz. Related products. Các mã hàng tương đương Mô đun Koyo D2-16NA: D2-04B-1 D2-06B-1 D2-08-ND3 D2-08TD1 D2-08TR D2-08TR D2-09B-1 D2-16NA D2-16ND3-2 D2-16TD1-2 D2-FILL. Supplier Links. D2-CTRINT F2-CP128 D2-EM D2-CM Programming Software The Do-more H2 Series PLC can only be programmed by Do-more Designer. or Best Offer. I have directsoft 5 and the unit is a Direct Logic 205 with a DL260 cpu and there is also a D2-16NA and a D2-08TR with this unit as well. If you need a specific series relating to 104-D180D24, we probably have it. The Do-more T1H series PLC power supplies are available in 120/240 VAC and 12/24 VDC input versions and multiple power supplies can be installed in a single system. 5500. d2-08tr, d3-016td1-2, se-sw9u-st, d2-260, se-sw5m-2st, f2-02da-2, f3-08thm-t, se-sw5u-sc, t1f-08da-1. 26–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay Modules D2-16NA 19 Feedthrough ZL-RTB20 ZL-D2-CBL19 * Do-more/DL205 PLC Analog Module ZIPLink Selector PLC ZIPLink Analog Module # of Terms Component Module Cable F2-04AD-1 10 D2-04TRS D2-08TR D2-12TR ZL followed by -TSD8 followed by -24 or -120. 1 Terminal Blocks and Wiring Solutions 1-800-633-0405 Legacy to New Generation Conversion Guide The following steps and charts will help in converting from the Legacy ZIPLink components to the new generation of ZIPLink wiring solutions. D2-16NA AC Input $204. AutomationDirect D2-CTRINT Counter Interface Module / Factory Surplus. (156g) Fuses None See Wiring Solutions for part numbers of ZIPLink cables and connection modules compatible with this I/O module. CUSTOM IDENTIFIER: AUTOMATION DIRECT D2-16NA D857887 ; Product details. 00 New. Either of these options should not affect the program. Author: AutomationDirect Created Date:D2-08NA-1 AC Input $116. 00 2600 None D2-09BDC1-1 $360. Tested and 2-Year Warranty. CSS ErrorModel Number(s) Model numbers included in the listing. PLC Direct DirectLogic 205 - DL205 discrete input module, 16- point, 120 VAC, 2 isolated common (s), 8 point (s) per common. 1 2 3 DL205 - Great Fit For On/Off Sequential Control 4 High-density modules save space and money, and can be wired in seconds using ZIPLinks The DL205 modules offer a variety of I/O density from four I/O points per module up to 32 I/O points per module. AUTOMATION DIRECT PMW-AN-1H SENSOR. 2 Caution: The D2-04TD1, D2-04TRS, and F2-08TRS outputs are derated not to exceed module specs 2A per point and 2A per common when used with theJ–2 DL205 User Manual, 5th Edition, Rev. View images and get all size and pricing details at Livabl. 00Automationdirect's D2-08TA is a dc input plc modules. CSS ErrorZIPLink Connection System Compatibility Chart 24–40 Connection Systems 1-800-633-0405 SPECIFYING AN I/O WIRING SYSTEM, (CONT. D2 D3 CIV A4 A5 A6 A7 VI B4 B5 B6 B7 VII C4 C5 C6 C7 VIII D4 D5 D6 D7 VIV D2-32TD2 ACT OUT 12-24 VDC 12-24VDC 0. Home; Products; Support; Downloads; Contact; Products. C Chapter 2: Installation, Wiring and Specifications Panel Mounting and Layout It is important to design your panel properly to help ensure the DL205 products operate within their environmental and electrical limits. $190. 9393. Webster, NY, United States. With 1 Year Warranty 1-800-991-7026 | 1-919-372-8413 | [email protected] 10 ZL-D2-CBL10-2 D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output. Ridgid Pipe Cutter No. 00 Inputs per Module 16 Commons per Module 2 (isolated) Input Voltage Range 80-132 VAC Peak Voltage 132VAC ON Voltage Level 70VAC minimum OFF Voltage Level 20VAC maximum AC Frequency 47-63 Hz Input Impedance 12 kΩ @ 60 Hz Input Current 11mA @ 100VAC, 50Hz 13mA @ 100VAC, 60HzUse this cross-reference table if you're looking for the equivalent PLC Direct parts for your "old" GE or TI/Siemens PLC system. DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. KOYO D2-16NA MODULE View product detail below. Jamie Marshall Jamie Marshall. D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. Associated . directlogic dl205 discrete input module, 16-point, 120 vac, 2 isolated common(s), 8 point(s) per com. 1601: RFQ: D2-FUSE-4: programmable controllers:D2-16NA 19 Feedthrough ZL-D2-CBL19 * Do-more/ DL205 PLC Output Module ZIPLink Selector PLC ZIPLink Output Module # of Terms Component Module Part No. D2-08NA-2 $99.